    1. ONLINE SERVICE
      TEL: 0086-577-27863300
      Mobile: 0086-13506674830
      E-mail: chziri@chziri.com
      Online QQ: 475341014
      Oneline Skype: Skype

      Product

      Home >> Product
      ZVF9V-M Mini Type AC motor drive
      ZVF9V-M Mini Type AC motor drive designed and produce according to the requirements of customers, has been in the market for reference customers widely tested by the characteristics of ZVF11 - M frequency drive . And on this basis to further perfect function, better meet the needs of the client application. ZVF9V-M Mini type AC motor drive can be installed in parallel, to save the space, Convenient installation.
      Specification:
      Single phase, 220V ± 20%, 0.75 to 2.2kW
      Three phase, 380V ± 20%, 0.75 to 2.2kW
      Clicks: 4401

      ZVF9V-M Mini Type vector control VFD

      Input Voltage(V) Output Voltage (V) Power Range (kW)
      Single phase 220V± 20% Three phase 0~input voltage 0.75kW~2.2kW
      Three phase 380V± 20% Three phase 0~input voltage 0.75kW~2.2kW

      Overload Capacity : 150% 1 minute ;180% 1 second ;200% transient protection .

      Technical Indications :
      1.Control Mode: SAPWM vector control .
      2.Output  Frequency range: 0.00~400.00HZ
      3.Operation command selection : Keyboard control ,Terminal Control, Multi-stage control , External analog voltage input control . External analog current input control .RS485 control .
      4.Frequency setting Mode: Digit keypad   setting, Analog setting ( current , voltage signal ). Remote communication  setting , Multi-step speed setting. Terminal assembled setting  . PID closed-loop setting.
      5.Start torque control :0-20% can be adjusted .
      6.Carrier frequency range:1.0K~15KHz
      7.DC current braking : Start and stop DC current braking can be adjusted solely .
      8. Automatism voltage Modulate : ( AVR):  Automatically keep output voltage  stable when input voltage fluctuation .
      9.Automatic limiting current : can limit  the Maximum current of the motor. And can protect the inverter and the motor reliably.
      10. PLC programmable  control: Single Cycle, continuous loop, wobble control and are suitable  for  all kinds of applications
      11.Input ,output terminal are programmable and It’s convenient for user.
      12.Analog signals output , voltage and current can be selected .

      Inverter Model Voltage
      (V)
      Power
      (KW)
      Current
      ( A)
      Dimension (mm)
      H W A B D d
      ZVF9V-M0007S2 220V 0.75 4.0 151.0 100 140.0 89.5 116.5 Ф5
      ZVF9V-M0015S2 1.5 7.5 151.0 100 140.0 89.5 116.5 Ф5
      ZVF9V-M0022S2 2.2 10 151.0 100 140.0 89.5 116.5 Ф5
      ZVF9V-M0007T4S 380V 0.75 2.3 151.0 100 140.0 89.5 116.5 Ф5
      ZVF9V-M0015T4S 1.5 3.7 151.0 100 140.0 89.5 116.5 Ф5
      ZVF9V-M0022T4S 2.2 5.0 151.0 100 140.0 89.5 116.5 Ф5

      Item

      Item Description

      Input

      Rated voltage frequency

      Single/three-phase 220VAC,three-phase 380VAC,50Hz/60Hz

      Allowable voltage range

      Voltage fluctuation range:-20%~+20%
      Voltage unbalance rate<3%;frequency fluctuation≤±5%

      Output

      Rated voltage

      Three-phase 0~input voltage VAC

      Frequency

      0.00~400.00Hz

      Overload capacity

      Type G:150% 1 minute; 180% 1 second;200% transient protection

      Control function

      Modulation

      Optimal space voltage vector PWM modulation

      Control method

      Speed sensorless vector control (SVC)

      Frequency accuracy

      Digital setting: Max. frequency ×±0.01%
      Analog setting:Max.Frequency×±0.2%

      Frequency resolution

      Digital setting:0.01Hz  Analog setting; Max. Frequency ×0.1%

      Starting frequency

      0.00~10.00Hz

      Torque lifting

      Automatic torque lifting: To lift the torque automatically
      According to the output current.
      Hand-operated torque lifting: Range: 0.1~30.0%

      Slip compensation

      Setting range:0~150%.The inverter output frequency can be auto-
      Regulated within this range according to the motor load so as to reduce
      The speed variation of the motor due to load fluctuation

      Acceleration/deceleration
      Time

      0.1~3600.0 sec/min ,which can be set in sequence

      Carrier frequency

      1.0~15.0KHz

      Jog function

      Jog frequency range:0.01~400.0Hz Jog acceleration/deceleration
      Time,0.13600.0 can be set

      V/F curve

      1.linear curve; 2.quadratic curve(conic); 3.User defined V/F curve

      Control Function

      Automatic
      energy-saving
      operation

      Auto optimize V/F curve according to load fluctuation
      To realize energy-saving operation.

      Auto voltage
      regulation (AVR)

      When the network voltage changes, it can regulate
      PWM output automatically to maintain constant voltage.

      Built-in PID

      This can form a convenient closed-loop control system
      (CLCS),and is applicable to pressure control, flow
      control and other process control.

      Operating function

      Operating command

      Operator panel control ,external terminal control and COM control

      DC braking

      Panel potentiometer setting, operator panel ▲▼ setting, external
      Terminal up/down setting, analog voltage signal or external potentiometer
      Setting, analog current signal setting, analog assembly setting,485 COM
      Setting and etc

      Input Signal

      Forward/Reverse signal, multiple speed signal, failure signal,
      reset signal and etc.

      Output signal

      Programmable relay, open-collector output, failure signal output and etc.

      Multi-function analog
      and digital output
      terminal

      This can realize the output of frequency, current and other physical
      quantity by outputting 0~20mA DC signal and 0~10KHz
      digital signal

      Braking function

      Dynamic braking

      With an external braking resistor, the maximum braking
      torque may reach 100% .

      DC braking

      This can be selected when the motor starts or stops with the
      Action frequency of 0~30 sec., which can be set in sequence

      Other functions

      Leap frequency, Jog function, counter to rotating speed, instant
      shutdown restarting, Frequency upper/lower limitation, acceleration/
      deceleration mode regulating, frequency meter and voltmeter output,
      multiple speed/program operation, two-wire/three wire control,
      vibration frequency control, Multi-function input terminal selection,
      Failure auto reset and 485COM.

      Protection function

      Input open-phase protection, over-current protection,
      overload protection, under voltage protection,
      overheating protection and etc.

         